When providing perioperative care, clinicians may benefit from continuous monitoring of key physiologic measurements and intuitive centralised displays of real-time patient data. Masimo offers multiple advanced noninvasive and continuous monitoring technologies, available on a single integrated platform and on select third-party multi-parameter monitors.
Masimo's breakthrough Signal Extraction Technology® (SET®) overcomes the limitations of conventional pulse oximetry with the ability to measure through motion and low perfusion.
Masimo rainbow SET™ technology, which leverages multiple additional wavelengths of light, is a suite of noninvasive measurements including total haemoglobin (SpHb®) and dyshaemoglobins. The rainbow SET technology platform also uniquely offers Pleth Variability Index (PVi®), a noninvasive dynamic parameter that helps clinicians monitor fluid responsiveness in mechanically-ventilated patients, and Oxygen Reserve Index (ORi™ ), a noninvasive and continuous parameter that provides insight into the oxygen reserve of patients receiving supplemental oxygen.
With measurement innovation at its core, Masimo has continued to expand its monitoring technologies to include brain function monitoring and cerebral oximetry. Masimo’s Next Generation SedLine® brain function monitoring features an enhanced processed EEG index (PSi) with four leads of bilateral EEG, less susceptibility to EMG interference, and improved performance in low power EEG cases.
These monitoring solutions are available on the Root® patient monitoring and connectivity platform, as well as on select third-party multi-parameter monitors. Root’s plug-and-play expansion capabilities allow clinicians to centralise patient monitoring by bringing together rainbow SET Pulse CO-Oximetry, Next Generation SedLine brain function monitoring, and O3 regional oximetry on an easy-to-interpret, customisable display, providing clinicians with more information for patient assessment.
Noninvasive and continuous SpHb provides real-time visibility to changes, or lack of changes, in haemoglobin between invasive blood samples
SpHb trend monitoring may provide additional insight between invasive blood samples when:
PVi is a noninvasive dynamic parameter that helps clinicians monitor fluid responsiveness in mechanically-ventilated patients
ORi is a noninvasive and continuous parameter intended to provide insight into a patient’s oxygen status in the moderate hyperoxic range, defined as a patient’s oxygen “reserve”
ORi with Masimo SET® pulse oximetry may provide:
Next Generation SedLine features an enhanced processed EEG index (PSi) and an enhanced Multitaper Density Spectral Array (DSA).
Next Generation SedLine provides a more complete picture of the brain with:
O3 Regional Oximetry uses near-infrared spectroscopy (NIRS) to enable monitoring of cerebral tissue oxygen saturation (rSO2)
Kite expands visibility of patient data on Root via a supplemental display
ORi has obtained CE Marking. Not available in the U.S. or Canada.
SpHb monitoring is not intended to replace laboratory blood testing. Blood samples should be analysed by laboratory instruments prior to clinical decision making.
For professional use. See instructions for use for full prescribing information, including indications, contraindications, warnings, and precautions.